• Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC
  • Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC
  • Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC
  • Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC
  • Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC
  • Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC

Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC

Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Single
Core: Core-type Transformer
Cooling Method: Dry-type Transformer
Winding Type: Separated Winding Transformer
Certification: ISO9001-2000, ISO9001, CCC
Samples:
US$ 5000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Jiangsu, China
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Fast Delivery
The supplier can deliver the goods within 30 days
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (30)
  • Overview
  • Product Description
  • Product Feature
  • More Product Parameters
  • FAQ
Overview

Basic Info.

Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
OD
Brand
ABB
Warranty
12 Months
ODM
Avaliable
OEM
Avaliable
MOQ
One
Transport Package
Wooden Case
Specification
as per design
Trademark
liyang electric
Origin
China
HS Code
8504330000
Production Capacity
6000pieces/Year

Product Description

 

Product Description

Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC
1.Three leg core:Made of grain oriendted low loss electrolami nations insulated on both sides.
2.Resilient spacers:To insulate core and windings from mechanical vibrations,resulting in low noise emissions.
3.HV winding:Consisting of vacuum potted single foil type aluminum or copper coils.
4.LV winding:Made of copper or aluminum strip.Turns firmly glued together by means of insulating sheet wrapper material.
5.Insulation:Mixture of epoxy resin and quatrz powder.Makes the transformer maintenance free,moistureproof,tropicalized,flame resistant and self extinguishing.
6.Clamping frame and truck:Rollers can be swung around for lengthways or sideways travel.
7.LV terminals:
Normal arrangement:top,rear.
Special version:Bottom,available on request at extra charge.
8.HV terminals:Variable arrangerments,for optimal station design.HV tapping links on low voltage side for adjust ment to system conditions,reconnectable in deenergized state.
 
Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC
Three Phase Dry Type Transformer Core Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC

The core is beveled and stepped for maximum performance and minimal bulk. After the magnetic steel is produced by the cutting machine, it is continuously cut into specific lengths by the automatic stacking machine, and then automatically stacked. The correct size is ensured during the entire stacking and assembly process to ensure the high quality of the product.

Dry Type Distribution Transformer Winding

Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC
The low voltage winding adopts the whole section of copper foil, which is wound on the special low-voltage foil winding machine with the F-grade insulation. The foil coil solves the outstanding problems such as low voltage, high current coil winding, high short-circuit stress, unbalanced ampere turns, poor heat dissipation effect, windingspiral angle, unstable manual welding quality and so on. At the same tim-e, the winding ends of our company aresealed with resin, cured and formed, moisture-proof and antifouling. The lead copper bar is automatically welded byargon arc welding.

Dry Type Power Transformer Accessories

All the accessories you need to customize our products to your needs.
The casing is made from bolts on a steel plate with removable panels for attachment and tape. Depending on the application and your requirements, the surface treatment can be galvanized, painted. The design is optimized to ensure the required cooling of the transformer at all levels of protection. The enclosure can be shipped assembled on the transformer or flat packed for on-site assembly.
Other Accessories
cooling fan.
Temperature monitoring unit (thermal control system)

Product Feature

1. Low loss, low noise, low partial discharge.
2. Strong anti-short circuit capability and high anti-lightning impact level.
3. Excellent moisture resistance for operation at 100% relative humidity.
4. Strong overload capability for long-term operation at 150% loading. 

Temperature control device:

The transformer adopts the BWDK series signal thermometer. The temperature measuring element is embedded in the upper half of the low-voltage coil, which can automatically detect and display the respective working temperature of the phase coil, and has the function of over temperature alarm and trip.

More Product Parameters

SCB10 10kV Epoxy-resin Insulation Dry-type Transformer 
Rated Capacity(kVA) Voltage Combined Vector-group No-load Loss(W) 75ºC
Load Loss(W)
No-load current(%) Short-circuit Impendance(%)
High voltage(KV) Tapping Ranges Low voltage(KV)
30 6

6.3

6.6

10

10.5

11
±5%
±2×2.5%
0.4 Dyn11

Yyn0
190 710 2.4 4
50 270 1000 2.4
80 370 1380 1.8
100 400 1570 1.8
125 470 1850 1.6
160 540 2130 1.6
200 620 2530 1.4
250 720 2760 1.4
315 880 3470 1.2
400 980 2990 1.2
500 1160 4880 1.2
630 1340 5880 1.0
630 1300 5960 1.0 6
800 1520 6960 1.0
1000 1770 8130 1.0
1250 2090 9690 1.0
1600 2450 11730 1.0
2000 6050 14450 0.8
2500 3600 17170 0.8
1600 2450 12960 1.0 8
2000 3050 15960 0.8
2500 3600 18890 0.8

SCB1110kV Epoxy-resin Insulation Dry-type Transformer 
Rated Capacity(kVA) Voltage Combined Vector-group No-load Loss(W) 75ºC
Load Loss(W)
Short-circuit Impendance(%) Size(mm) Track gauge(mm)
High voltage(KV) Tapping Ranges Low voltage(KV)
30 6

10

10.5

11
±5% 0.4 Dyn11

Yyn0
180 560 4 800x660x940 400x400
50 260 730 830x690x990 400x400
80 320 1120 860x690x1020 400x400
100 350 1370 900x720x1060 550x550
125 430 1620 940x740x1080 550x550
160 480 1900 1220x770x1100 550x550
200 540 2100 1240x780x1170 550x550
250 650 2560 1390x800x1200 550x550
315 760 3010 1410x820x1230 550x550
400 780 3690 1500x860x1270 660x660
500 840 4300 1520x870x1520 660x660
630 1040 5160 6 1600x890x1410 660x660
800 1240 6290 1660x950x1460 820x820
1000 1430 7380 1760x970x1500 820x820
1250 1500 8830 1800x1090x1620 820x820
1600 1710 10580 1870x1100x1700 820x820
2000 2200 12810 1980x1180x1800 1070x1070
2500 2650 15080 2090x1260x1930 1070x1070
SCB13 10kV Epoxy-resin Insulation Dry-type Transformer
Rated Capacity(kVA) Voltage Combined Vector-group No-load Loss(W) Load Loss under Different Insulation and Heat Resistance Levels No-load current(%) Short-circuit Impendance(%)
High voltage(KV) Tapping Ranges Low voltage(KV) B(100ºC) P(120ºC) H(145ºC)
30 6

6.3

6.6

10

10.5

11
±5%
±2×2.5%
0.4 Dyn11

Yyn0
150 670 710 760 2.4 4.0
50 215 940 1000 1070 2.4
80 295 1290 1380 1480 1.8
100 320 1480 1570 1690 1.8
125 375 1740 1850 1980 1.6
160 430 2000 2130 2280 1.6
200 495 2370 2530 2710 1.4
250 575 2590 2760 2960 1.4
315 705 3270 3470 3730 1.2
400 785 3750 3990 4280 1.2
500 930 4590 4880 5230 1.2
630 1070 5530 5880 6290 1.0
630 1040 5610 5960 6400 1.0 6.0
800 1215 6550 6960 7460 1.0
1000 1415 7650 8130 8760 1.0
1250 1670 9100 9690 10370 1.0
1600 1960 11050 11730 12580 1.0
2000 2440 14450 14450 15560 0.8
2500 2880 17170 17170 18450 0.8
SCB14 10kV Epoxy-resin Insulation Dry-type Transformer 
Rated Capacity(kVA) Voltage Combined Vector-group No-load Loss(W) Load Loss under Different Insulation and Heat Resistance Levels No-load current(%) Short-circuit Impendance(%)
High voltage(KV) Tapping Ranges Low voltage(KV) B(100ºC) P(120ºC) H(145ºC)
30 6

6.3

6.6

10

10.5

11
±5%
±2×2.5%
0.4 Dyn11

Yyn0
130 605 640 685 2.4 4.0
50 185 845 900 965 2.4
80 250 1160 1240 1330 1.8
100 270 1330 1415 1520 1.8
125 320 1565 1665 1780 1.6
160 365 1800 1915 2050 1.6
200 420 2135 2275 2440 1.4
250 490 2330 2485 2665 1.4
315 600 2945 3125 3355 1.2
400 665 3375 3590 3850 1.2
500 790 4130 4390 4705 1.2
630 910 4975 5290 5660 1.0
630 885 5050 5365 5760 1.0 6.0
800 1035 5895 6265 6715 1.0
1000 1205 6885 7315 7885 1.0
1250 1420 8190 8720 9335 1.0
1600 1665 9945 10555 11320 1.0
2000 2075 12240 13005 14005 0.8
2500 2450 14535 15445 16605 0.8
SCB18 10kV Epoxy-resin Insulation Dry-type Transformer 
Rated Capacity(kVA) Voltage Combined Vector-group No-load Loss(W) Load Loss under Different Insulation and Heat Resistance Levels No-load current(%) Short-circuit Impendance(%)
High voltage(KV) Tapping Ranges Low voltage(KV) B(100ºC) P(120ºC) H(145ºC)
30 6

6.3

6.6

10

10.5

11
±5%
±2×2.5%
0.4 Dyn11

Yyn0
105 605 640 685 2.4 4.0
50 155 845 900 965 2.4
80 210 1160 1240 1330 1.8
100 230 1330 1415 1520 1.8
125 270 1565 1665 1780 1.6
160 310 1800 1915 2050 1.6
200 360 2135 2275 2440 1.4
250 415 2330 2485 2665 1.4
315 510 2945 3125 3355 1.2
400 570 3375 3590 3850 1.2
500 670 4130 4390 4705 1.2
630 775 4975 5290 5660 1.0
630 750 5050 5365 5760 1.0 6.0
800 875 5895 6265 6715 1.0
1000 1020 6885 7315 7885 1.0
1250 1205 8190 8720 9335 1.0
1600 1415 9945 10555 11320 1.0
2000 1760 12240 13002 14005 0.8
2500 2080 14535 15445 16605 0.8

 

 

Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCCDry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCCDry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCCDry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC
Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC

Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC

Dry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCCDry-Type Liyang Electric Wooden Case as Per Design Dry Type Transformer with CCC
Payment Term
Payment Terms T/T EXW 30% T/T in advance, the balance to be paid before dispatch
FOB
CIF 30% T/T in advance, the balance to be paid against the copy of B/L
CFR (C&F)
L/C Irrevocable L/C at sight could be accepted if amount above US $50,000.00
Delivery Time 7 to 10 working days after receiving advanced payment
 

FAQ



Q:what's your major products?
A: oil immersed transformer, dry type transformer, Transformer Substation, High and Low Voltage Switchgear

Q: Can your product be customized?
A: Considering differences in voltage, frequency and other special transformer product in different countries and regions, our product can be customized according to your requirements.

Q: When can I get the price?
A:Usually we quote within 24 hours after we get your inquiry.

Q: What about lead or shipping time?
A: The lead time depends on the quantity you ordered, generally within 15 days upon receipt of advance payment.

Q: What is the price of shipping?
A: Depending upon the port of delivery, prices varies.

Q: Do you offer guarantee for the products?
A: Yes. We offer at least one years guarantee for all of our transformers.

Q: Your Advantage?
A: 15 years experience, Advanced production equipment, Stable quality, Fast delivery, Professional & good & Prompt service. Also some free parts can be provided for you.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now